<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>分水器 - 芯达科技</title>
	<atom:link href="https://www.aixinda.cn/product-category/manifold/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.aixinda.cn/product-category/manifold/</link>
	<description></description>
	<lastBuildDate>Thu, 08 Oct 2026 06:50:16 +0000</lastBuildDate>
	<language>zh-Hans</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://www.aixinda.cn/wp-content/uploads/2026/04/fav.png</url>
	<title>分水器 - 芯达科技</title>
	<link>https://www.aixinda.cn/product-category/manifold/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>定制铜制液冷服务器分集水器组件</title>
		<link>https://www.aixinda.cn/product/custom-copper-liquid-cooled-server-manifold-assemblies/</link>
		
		<dc:creator><![CDATA[cycocnc@gmail.com]]></dc:creator>
		<pubDate>Tue, 21 Jul 2026 07:29:20 +0000</pubDate>
				<guid isPermaLink="false">https://www.aixinda.cn/?post_type=product&#038;p=2508</guid>

					<description><![CDATA[<p>这个服务器分集水组件由高纯度铜制成，可以手动连接安装，灵活地在机架内垂直或水平布置，在冷板式液冷服务器和CDU之间提供接口，确保服务器液冷回路系统在长时间高负载和频繁温度变化的情况下，能够稳定高效地将热量从服务器锁有关键芯片（CPU、GPU等）带走，保证设备稳定运行。高精度的真空钎焊工艺焊接能确保服务器机架分集水管的每个焊点都没有气孔和裂纹，无漏液风险。</p>
<p>The post <a href="https://www.aixinda.cn/product/custom-copper-liquid-cooled-server-manifold-assemblies/">定制铜制液冷服务器分集水器组件</a> appeared first on <a href="https://www.aixinda.cn">芯达科技</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="table-responsive">
<table class="table table-bordered" width="1178" data-sort="sortDisabled">
<tbody>
<tr class="firstRow">
<td valign="top">产地:</td>
<td valign="top">中国惠州</td>
<td valign="top">原始散热器制造商:</td>
<td valign="top">是的</td>
</tr>
<tr>
<td valign="top">工序:</td>
<td valign="top">真空钎焊工艺</td>
<td valign="top">硬度:</td>
<td valign="top">T3-T8</td>
</tr>
<tr>
<td valign="top">材料:</td>
<td valign="top">铜C1100/C1220</td>
<td valign="top">形状:</td>
<td valign="top">方形</td>
</tr>
<tr>
<td valign="top">应用:</td>
<td valign="top">服务器、数据中心、高级计算机等</td>
<td valign="top">真空钎焊抗拉强度:</td>
<td valign="top">340-390N/mm ²</td>
</tr>
<tr>
<td valign="top">表面处理:</td>
<td valign="top">清洁、抗氧化</td>
<td valign="top">质量控制:</td>
<td valign="top">100%热测试</td>
</tr>
<tr>
<td valign="top">额外的过程:</td>
<td valign="top">数控加工</td>
<td valign="top">尺寸:</td>
<td valign="top"> 可定制</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.aixinda.cn/product/custom-copper-liquid-cooled-server-manifold-assemblies/">定制铜制液冷服务器分集水器组件</a> appeared first on <a href="https://www.aixinda.cn">芯达科技</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>AI液冷服务器分水器</title>
		<link>https://www.aixinda.cn/product/ai-liquid-cooled-server-manifold/</link>
		
		<dc:creator><![CDATA[cycocnc@gmail.com]]></dc:creator>
		<pubDate>Tue, 21 Jul 2026 03:01:16 +0000</pubDate>
				<guid isPermaLink="false">https://www.aixinda.cn/?post_type=product&#038;p=2457</guid>

					<description><![CDATA[<p>这款液冷服务器分水器采用无缝内抛光方管，耐腐蚀性强，强度高，为数据中心提供洁净且有效的液冷路线。芯达液冷歧管提供定制生产服务，采用超高精密度制造，根据客户进行加工定制，精度高达0.1mm。芯达的液冷机架歧管拥有单排管和双排管的选择，具有很强的灵活性，安装便携。芯达科技是液冷服务器和数据中心液冷组件和系统制造商和供应商，拥有先进的液冷技术，正在寻找数据中心液冷分水器，请联系我们，我们提供定制液冷歧管。</p>
<p>The post <a href="https://www.aixinda.cn/product/ai-liquid-cooled-server-manifold/">AI液冷服务器分水器</a> appeared first on <a href="https://www.aixinda.cn">芯达科技</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="table-responsive">
<table class="table table-bordered" width="1178" data-sort="sortDisabled">
<tbody>
<tr class="firstRow">
<td valign="top">产地:</td>
<td valign="top">中国惠州</td>
<td valign="top">原始散热器制造商:</td>
<td valign="top">是的</td>
</tr>
<tr>
<td valign="top">工序:</td>
<td valign="top">真空钎焊工艺</td>
<td valign="top">硬度:</td>
<td valign="top">T3-T8</td>
</tr>
<tr>
<td valign="top">材料:</td>
<td valign="top">铜/铝/不锈钢（可选择）</td>
<td valign="top">形状:</td>
<td valign="top">方形</td>
</tr>
<tr>
<td valign="top">应用:</td>
<td valign="top">服务器、数据中心、高级计算机等</td>
<td valign="top">公差:</td>
<td valign="top">0.05 mm</td>
</tr>
<tr>
<td valign="top">表面处理:</td>
<td valign="top">抛光</td>
<td valign="top">质量控制:</td>
<td valign="top">100%全检</td>
</tr>
<tr>
<td valign="top">额外的过程:</td>
<td valign="top">数控加工</td>
<td valign="top">尺寸:</td>
<td valign="top"> 可定制</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.aixinda.cn/product/ai-liquid-cooled-server-manifold/">AI液冷服务器分水器</a> appeared first on <a href="https://www.aixinda.cn">芯达科技</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>数据中心液冷系统液冷歧管</title>
		<link>https://www.aixinda.cn/product/liquid-cooling-manifold-for-data-center-liquid-cooling-systems/</link>
		
		<dc:creator><![CDATA[cycocnc@gmail.com]]></dc:creator>
		<pubDate>Tue, 21 Jul 2026 02:55:36 +0000</pubDate>
				<guid isPermaLink="false">https://www.aixinda.cn/?post_type=product&#038;p=2454</guid>

					<description><![CDATA[<p>这款液冷冷却水平歧管强度高、内壁抛光、自清洁、耐腐蚀，为数据中心服务器提供洁净且有效的液冷路线。芯达液冷歧管提供定制生产服务，采用超高精密度制造，根据客户进行加工定制，精度高达0.1mm。芯达的液冷机架歧管拥有单排管和双排管的选择，具有很强的灵活性，安装便携。</p>
<p>The post <a href="https://www.aixinda.cn/product/liquid-cooling-manifold-for-data-center-liquid-cooling-systems/">数据中心液冷系统液冷歧管</a> appeared first on <a href="https://www.aixinda.cn">芯达科技</a>.</p>
]]></description>
										<content:encoded><![CDATA[<div class="table-responsive">
<table class="table table-bordered" width="1178" data-sort="sortDisabled">
<tbody>
<tr class="firstRow">
<td valign="top">产地:</td>
<td valign="top">中国惠州</td>
<td valign="top">原始散热器制造商:</td>
<td valign="top">是的</td>
</tr>
<tr>
<td valign="top">工序:</td>
<td valign="top">真空钎焊工艺</td>
<td valign="top">硬度:</td>
<td valign="top">T3-T8</td>
</tr>
<tr>
<td valign="top">材料:</td>
<td valign="top">铜/铝/不锈钢（可选择）</td>
<td valign="top">形状:</td>
<td valign="top">圆形</td>
</tr>
<tr>
<td valign="top">应用:</td>
<td valign="top">服务器、数据中心、高级计算机等</td>
<td valign="top">公差:</td>
<td valign="top">0.05 mm</td>
</tr>
<tr>
<td valign="top">表面处理:</td>
<td valign="top">抛光</td>
<td valign="top">质量控制:</td>
<td valign="top">100%全检</td>
</tr>
<tr>
<td valign="top">额外的过程:</td>
<td valign="top">数控加工</td>
<td valign="top">尺寸:</td>
<td valign="top"> 可定制</td>
</tr>
</tbody>
</table>
</div>
<p>The post <a href="https://www.aixinda.cn/product/liquid-cooling-manifold-for-data-center-liquid-cooling-systems/">数据中心液冷系统液冷歧管</a> appeared first on <a href="https://www.aixinda.cn">芯达科技</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>分水器</title>
		<link>https://www.aixinda.cn/product/liquid-cooling-manifold/</link>
		
		<dc:creator><![CDATA[cycocnc@gmail.com]]></dc:creator>
		<pubDate>Fri, 08 May 2026 02:57:01 +0000</pubDate>
				<guid isPermaLink="false">https://www.xindaaitech.com/?post_type=product&#038;p=571</guid>

					<description><![CDATA[<p>分水器是一种用于流体分配与汇集的装置，其核心功能是将一路总管的流体按需求分配到多路支管，同时将多路支管的回流流体汇集到总管，是暖通系统中实现流量精确控制的关键部件。</p>
<p>分水器位于系统的供水端，负责将来自热源或冷源的流体（如热水、冷水）均匀地分配到各个支路循环中，保证各支路流量平衡。</p>
<p>The post <a href="https://www.aixinda.cn/product/liquid-cooling-manifold/">分水器</a> appeared first on <a href="https://www.aixinda.cn">芯达科技</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>分水器是一种用于流体分配与汇集的装置，其核心功能是将一路总管的流体按需求分配到多路支管，同时将多路支管的回流流体汇集到总管，是暖通系统中实现流量精确控制的关键部件。</p>
<p>分水器位于系统的供水端，负责将来自热源或冷源的流体（如热水、冷水）均匀地分配到各个支路循环中，保证各支路流量平衡。</p>
<div class="section-container">
<div class="two-column">
<div class="text-content">
<h3>分水器应用：</h3>
<h4>地板辐射采暖（地暖）</h4>
<p>分水器最典型的应用场景。将热水均匀分配至地板下的各个环路，实现全屋舒适、节能的低温辐射供暖。</p>
<h4>暖气片供暖系统</h4>
<p>用于集中连接并分配流量到多个暖气片，可配合温控阀实现精准的分室控温，满足不同房间的温度需求。</p>
<h4>中央空调水系统</h4>
<p>在水系统中央空调中，分水器负责将主机产生的冷冻水或热水高效分配到各个房间的风机盘管，实现制冷或制热。</p>
</div>
<div class="image-content"><img decoding="async" src="/wp-content/uploads/2026/05/fenshuiqi-2.jpg" /></div>
</div>
</div>
<h3>分水器工作原理：一个闭环过程</h3>
<h5>01 / 分流过程</h5>
<p>来自热源或冷源的流体，首先进入分水器的主管，开启循环第一步。</p>
<h5>02 / 分配过程</h5>
<p>流体在主管流动，通过多个分支接口，被精确分配到连接各个房间或区域的支路管道中。</p>
<h5>03 / 换热过程</h5>
<p>流体在支路管道中流动，完成预定功能：向房间释放热量或吸收热量，实现温控目标。</p>
<h5>04 / 回流过程</h5>
<p>完成能量交换后的流体，通过支路管道回流至集水器对应的各个分支接口，准备汇流。</p>
<h5>05 / 汇流过程</h5>
<p>所有支路回流的流体在集水器主管汇集，最终通过主回流管返回热源或冷源，完成闭环。</p>
<p><img fetchpriority="high" decoding="async" class="alignnone size-full wp-image-2093" src="https://www.aixinda.cn/wp-content/uploads/2026/06/guanlei.jpg" alt="" width="1300" height="1135" srcset="https://www.aixinda.cn/wp-content/uploads/2026/06/guanlei.jpg 1300w, https://www.aixinda.cn/wp-content/uploads/2026/06/guanlei-350x306.jpg 350w, https://www.aixinda.cn/wp-content/uploads/2026/06/guanlei-1024x894.jpg 1024w, https://www.aixinda.cn/wp-content/uploads/2026/06/guanlei-768x671.jpg 768w, https://www.aixinda.cn/wp-content/uploads/2026/06/guanlei-600x524.jpg 600w" sizes="(max-width: 1300px) 100vw, 1300px" /></p>
<p>The post <a href="https://www.aixinda.cn/product/liquid-cooling-manifold/">分水器</a> appeared first on <a href="https://www.aixinda.cn">芯达科技</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
